Knürr 19" Fire Protection System back  
 
Knürr AG - Space-optimised fire protection for 19" server racks, network racks and telecommunication

Knürr AG - Space-optimised fire protection for 19" server racks, network racks and telecommunication
 

Space-optimised fire protection for 19" server racks

The “earliest” detection for the fastest possible reaction can make the differ-
ence between total destruction and maximum damage limitation. Knürr focuses on smoke detection for early alertness to guarantee this.

The smoke is detected using optical systems. Knürr uses patented smoke aspiration systems for highly-sensitive detection of even the smallest amount of smoke particles.

EDP, server and control racks are among the most important technical components in every company. They manage the internal and external data flow or control production processes, among other functions. However in many cases these racks are not centrally situated, and not or only insufficiently integrated into existing safety systems. Use in concen-
trated data centers for local detection and, where applicable, only partial intervention, is also an indispensable factor.
  The compact earliest smoke detection system is the solution for both areas.

The easy to handle and space-saving
19-inch slot-in (1 U) detects fires and enables automatic countermeasures in server racks - reliably and efficiently.
An integrated smoke aspiration system detects potential fire as early as possible. The subsequent automatic power-off takes the energy for spreading away from the fire. A fire extinguishing system is also an optional control. The new system, which is suitable for all EDP, server and control racks in 19-inch versions, unites optimum space-saving and the best possible fire detection and fire extinguishing qualities for the first time.

An exceptional feature is provided by the tried, tested and proven unrestricted use in circulated air-cooled systems (Knürr CoolTherm).

- Ultra-flat 19” earliest smoke detection system for protecting 19” racks.

- The integrated smoke aspiration unit has also been developed and tested for   circulating aircooling systems (Knürr CoolTherm®).

Applications
- EDP, server and control racks in 19” version

Main features
- Earliest smoke detection
- False alarms ruled out by intelligent signal processing
- Safe and secure equipment monitoring
- Easy installation and start-up with Plug & Play

Features
- Integrated system for fire detection and extinguishing
- Up to 400 times more sensitive in detecting fires than conventional smoke detectors
- High certainty that false alarms will not occur with fire pattern detection
- No unnecessary wastage of server space with 1 HU installation height
- Vertical and horizontal installation possible
- Individual response behaviour adjustment
- Simple and straightforward mounting
- Maintenance with interactive diagnostics without operation interruption
- Central monitoring, remote diagnostics and remote maintenance with networking
- Optional use of two detector modules for two sensor dependence
- Optional control of a fire extinguishing system
 